Background: The diagnostic accuracy of high-resolution ultrasonography (HRUS) in comparison to electro-diagnostic testing (EDX) in carpal tunnel syndrome (CTS) is debatable. Objective: The aim of this study was to compare the diagnostic accuracy of HRUS with EDX in patients with various grades of CTS and CTS associated with peripheral neuropathy (CTS + PNP). Materials and Methods: A prospective cohort of 57 patients with possible CTS was studied along with matched controls. The cross-sectional area (CSA) of the median nerve at the inlet of carpal tunnel was assessed by a sonologist blinded to the clinical and EDX data. Palm wrist distal sensory latency difference (PWDSLD), second lumbrical-interosseus distal motor latency difference (2LIDMLD) and CSA were compared in patients with different grades of severity of CTS and CTS+PNP. Results: Total 92 hands of 57 patients met the clinical criteria for CTS. Mean CSA at the inlet of carpal tunnel was 0.11 ± 0.0275 cm 2 . It had the sensitivity, specificity, positive predictive value and negative predictive values of 76.43%, 72.72%, 89.47% and 68%, respectively (P < 0.0001). Overall, HRUS had good correlation with PWDSLD and 2LIDMLD electro-diagnostic studies in all grades of CTS and CTS + PNP. Conclusion: HRUS can be used as a complementary screening tool to EDX. However, EDX has been found to be more sensitive and specific in mild CTS.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2800    
    Printed36    
    Emailed0    
    PDF Downloaded87    
    Comments [Add]    
    Cited by others 1    

Recommend this journal