”Missing clot” during mechanical thrombectomy in acute stroke using Solitaire stent retrieval system


Departments of Interventional Neurology and Stroke, NH Institute of Neurosciences, NH Health City, Bangalore, Karnataka, India

Date of Submission15-Oct-2015
Date of Decision13-Nov-2015
Date of Acceptance17-Dec-2015
Date of Web Publication12-May-2016

Correspondence Address:
Vikram Huded
Department of Interventional Neurology and Stroke, Narayana Institute of Neurosciences, NH Health City, Bangalore - 560 099, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-2327.176866

Rights and Permissions

 

   Abstract 

Stent retrieval system is an established treatment modality in acute ischemic stroke with large vessel occlusion. Here, we describe a complication which occurred during mechanical thrombectomy in three cases where the clot dislodged during retrieval. There was a possibility of the clot getting reinjected into the artery with possible dire consequences.


Keywords: Acute stroke, mechanical thrombectomy, solitaire


How to cite this article:
Huded V, Nambiar V, De Souza R, Bohra V, Ramankutty R. ”Missing clot” during mechanical thrombectomy in acute stroke using Solitaire stent retrieval system. Ann Indian Acad Neurol 2016;19:279-80

How to cite this URL:
Huded V, Nambiar V, De Souza R, Bohra V, Ramankutty R. ”Missing clot” during mechanical thrombectomy in acute stroke using Solitaire stent retrieval system. Ann Indian Acad Neurol [serial online] 2016 [cited 2019 Nov 21];19:279-80. Available from: http://www.annalsofian.org/text.asp?2016/19/2/279/176866



   Introduction Top


Mechanical thrombectomy using stent retrievers is an established treatment modality in patients with acute ischemic stroke with a proximal large vessel occlusion. Recent trials have shown shorter recanalization time, better recanalization rates, and reduced mortality with newer generation stent retrievers making them the most preferred of the available options in the management of acute ischemic stroke due to large vessel occlusions.[1],[2],[3] However, there may be unexpected complications and technical challenges as well.

In this case, of a series of three patients, we describe the technical difficulty we encountered while attempting clot retrieval using a stent retrieval device. We hope that awareness about such technical problems will help to prevent unexpected procedural complications.


   Case Report Top


From January 2010 to June 2015, 73 patients of acute ischemic stroke were treated with endovascular treatment with or without intravenous recombinant tissue plasminogen activator (rTPA) at our institution. In three patients we met with technical difficulties while performing thrombus aspiration and retrieval, which we describe as the “missing clot” in mechanical thrombectomy. All three patients had cardioembolic stroke with carotid “T” or M1 occlusion.

Procedure

After inserting 9 French Femoral sheath and 8 French Corail guiding catheter with balloon, a Rebar 18/27 microcatheter was passed beyond the thrombus. Solitaire stent of 4 × 20 or 6 × 30 was used for retrieval. A temporary deployment of the stent for 5 min showed forward filling in the arteries, after which the stent was retrieved. This was done while simultaneous aspiration was done by an assistant using a 50 cc syringe, through the “Y” connector that is attached to the Corail guiding catheter. This negative aspiration is continued till the stent is out of the sheath. Usually we expect the thrombus and debris to be caught in the stent or in the syringe in case it is dislodged from the stent struts.

In these three patients, the thrombus was missing from stent struts and in the syringe aspirate and there was not much aspirate in the guiding catheter as well, after retrieval. The possibility of the “missing clot” being caught somewhere in the guide catheter was considered so the guide catheter was slowly pulled out maintaining continuous aspiration. To our surprise, there was a large clot at the tip of the guiding catheter, stuck in the femoral sheath valve. We had to remove the cap of the sheath with the valve, where we found a large chunk of rubbery fibrous thrombus stuck in the valve opening [Figure 1]. All three patients achieved thrombolysis in cerebral infarction (TICI) 3 recanalization. The clinical outcome was good (mRS0-1) in two patients and poor (mRS 3-6) in the third patient at 1 week post ictus.
Figure 1: Large thrombus seen at the valve sheath

Click here to view



   Discussion Top


Stent retrieval systems are the preferred mechanical thrombectomy devices in the recent times. The main mechanism of clot retrieval by a stent retriever is the initial thrust by the stent on the vessel wall that allows separation of the clot and entrapment of the body of the clot into stent struts. The safety and efficacy of stent retrievers in acute stroke is documented in several studies; nevertheless, complications may occur.[4] The dislodgement of thrombus distal to the site of occlusion and embolization to uninvolved vessel is described in 1.7% of patients in a randomized trial. Other major adverse events reported are: Subarachnoid hemorrhage, permanent stent deployment, stent entrapment, and rupture of the vessel.[4],[5]

The peculiar technical problem that we encountered was in a series of cardioembolic strokes. There have been several case reports from single centers describing their experiences and the complications they encountered using stent retrievers.[5],[6],[7],[8]

If the missing clot that we describe here is detected early, we can avoid distal embolization during reinjection into the catheter. Suspicion should arise when there is no aspirate in the guiding catheter after retrieving the stent. In the present cohort of patients, there was associated chronic atrial fibrillation secondary to mitral valve disease indicating that the well-organized left atrial thrombus was the cause. The other technical fact to be considered is that in the present instance, even after the guiding catheter was pulled out, the clot got trapped at the sheath outlet due to its size and fibrous nature. If the sheath was flushed, it could have led to unexpected embolization with possible disastrous consequences.

Stent retrieval systems are becoming popular for endovascular treatment of acute ischemic strokes. It is important to remember that if there is no clot found in the stent retriever or in the aspiration syringe, there is a possibility that the clot has been dislodged somewhere in the system that could include the guiding catheter or even the sheath. Thus, caution should be exercised before flushing of the sheath or the guiding catheter.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Stent-Retriever Thrombectomy after Intravenous t-PA vs. t-PA Alone in Stroke — NEJM. Available from: target="_blank" href="http://www.nejm.org/doi/full/10.1056/NEJMoa1415061". [Last accessed on 2015 Aug 18].  Back to cited text no. 1
    
2.
Randomized Assessment of Rapid Endovascular Treatment of Ischemic Stroke — NEJM. Available from: target="_blank" href="http://www.nejm.org/doi/full/10.1056/NEJMoa1414905". [Last accessed on 2015 Aug 18].  Back to cited text no. 2
    
3.
Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging Selection — NEJM. Available from: target="_blank" href="http://www.nejm.org/doi/full/10.1056/NEJMoa1414792". [Last accessed on 2015 Aug 18].  Back to cited text no. 3
    
4.
Kim JE, Kim AR, Paek YM, Cho YJ, Lee BH, Hong KS. Safety and efficacy of mechanical thrombectomy with the solitaire device in large artery occlusion. Neurol India 2012;60:400-5.  Back to cited text no. 4
[PUBMED]  Medknow Journal  
5.
Kim TK, Rhim JK, Lee CJ, Oh SH, Chung BS. The limitations of thrombectomy with Solitaire AB as first-line treatment in acute ischemic stroke: A single center experience. J Cerebrovasc Endovasc Neurosurg 2012;14:203-9.   Back to cited text no. 5
    
6.
Preliminary Experience with the use of Self-Expanding Stent as a Thrombectomy Device in Ischemic Stroke — PubMed - NCBI. Available from: target="_blank" href="http://www.ncbi.nlm.nih.gov/pubmed/21535945". [Last accessed on 2015 Aug 18].  Back to cited text no. 6
    
7.
Miteff F, Faulder KC, Goh AC, Steinfort BS, Sue C, Harrington TJ. Mechanical thrombectomy with a self-expanding retrievable intracranial stent (Solitaire AB): Experience in 26 patients with acute cerebral artery occlusion. AJNR Am J Neuroradiol 2011;32:1078-81.   Back to cited text no. 7
    
8.
Dorn F, Stehle S, Lockau H, Zimmer C, Liebig T. Endovascular treatment of acute intracerebral artery occlusions with the solitaire stent: Single-centre experience with 108 recanalization procedures. Cerebrovasc Dis 2012;34:70-7.  Back to cited text no. 8
    


    Figures

  [Figure 1]



 

Top
Print this article  Email this article

    

 
   Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (623 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
   Case Report
   Discussion
    References
    Article Figures

 Article Access Statistics
    Viewed1505    
    Printed30    
    Emailed0    
    PDF Downloaded57    
    Comments [Add]    

Recommend this journal