Annals of Indian Academy of Neurology
ORIGINAL ARTICLE
Year
: 2015  |  Volume : 18  |  Issue : 2  |  Page : 219--225

Comparison of high-resolution sonography and electrophysiology in the diagnosis of carpal tunnel syndrome


Meena Angamuthu Kanikannan, Demudu Babu Boddu, Umamahesh, Sailaja Sarva, Padmaja Durga, Rupam Borgohain 
 Department of Neurology, and Radiology, Nizam's Institute of Medical Sciences, Punjagutta, Hyderabad, Andhra Pradesh, India

Correspondence Address:
Meena Angamuthu Kanikannan
Department of Neurology, Nizam«SQ»s Institute of Medical Sciences, Punjagutta, Hyderabad - 500 082, Andhra Pradesh
India

Background: The diagnostic accuracy of high-resolution ultrasonography (HRUS) in comparison to electro-diagnostic testing (EDX) in carpal tunnel syndrome (CTS) is debatable. Objective: The aim of this study was to compare the diagnostic accuracy of HRUS with EDX in patients with various grades of CTS and CTS associated with peripheral neuropathy (CTS + PNP). Materials and Methods: A prospective cohort of 57 patients with possible CTS was studied along with matched controls. The cross-sectional area (CSA) of the median nerve at the inlet of carpal tunnel was assessed by a sonologist blinded to the clinical and EDX data. Palm wrist distal sensory latency difference (PWDSLD), second lumbrical-interosseus distal motor latency difference (2LIDMLD) and CSA were compared in patients with different grades of severity of CTS and CTS+PNP. Results: Total 92 hands of 57 patients met the clinical criteria for CTS. Mean CSA at the inlet of carpal tunnel was 0.11 ± 0.0275 cm 2 . It had the sensitivity, specificity, positive predictive value and negative predictive values of 76.43%, 72.72%, 89.47% and 68%, respectively (P < 0.0001). Overall, HRUS had good correlation with PWDSLD and 2LIDMLD electro-diagnostic studies in all grades of CTS and CTS + PNP. Conclusion: HRUS can be used as a complementary screening tool to EDX. However, EDX has been found to be more sensitive and specific in mild CTS.


How to cite this article:
Kanikannan MA, Boddu DB, Umamahesh, Sarva S, Durga P, Borgohain R. Comparison of high-resolution sonography and electrophysiology in the diagnosis of carpal tunnel syndrome.Ann Indian Acad Neurol 2015;18:219-225


How to cite this URL:
Kanikannan MA, Boddu DB, Umamahesh, Sarva S, Durga P, Borgohain R. Comparison of high-resolution sonography and electrophysiology in the diagnosis of carpal tunnel syndrome. Ann Indian Acad Neurol [serial online] 2015 [cited 2019 Sep 15 ];18:219-225
Available from: http://www.annalsofian.org/article.asp?issn=0972-2327;year=2015;volume=18;issue=2;spage=219;epage=225;aulast=Kanikannan;type=0